Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves

234Citations
Citations of this article
147Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims We sought to evaluate the frequency of early hypo-attenuated leaflet thickening (HALT) of the SAPIEN 3 transcatheter aortic valve (S3). Methods and results Of 249 patients who had undergone S3 implantation, we studied 156 consecutive patients (85 women, median age 82.2 ± 5.5 years) by electrocardiogram (ECG)-triggered dual-source computed tomography angiography (CTA) after a median of 5 days post-transcatheter aortic valve implantation. The prosthesis was assessed for HALT. Apart from heparin, peri-interventional antithrombotic therapy consisted of single- (aspirin 29%) or dual- (aspirin plus clopidogrel 71%) antiplatelet therapy. Hypo-attenuated leaflet thickening was found in 16 patients [10.3% (95% confidence interval (CI) 5.5-15.0%)] of the patients. None of the baseline and procedural variables were significantly associated with HALT, nor did we find a significant association with the antithrombotic regimen, either peri-interventionally or at the time of CTA. Hypo-attenuated leaflet thickening was found in 6 of 45 patients with peri-interventional single-antiplatelet therapy and in 10 of 111 patients with dual-antiplatelet therapy at the time of intervention [13.3% (95% CI 3.4-23.3%) vs. 9% (95% CI 3.7-14.3%), P = 0.42]. Hypo-attenuated leaflet thickening was not associated with clinical symptoms, but a small, albeit significant difference in mean pressure gradient at the time of CTA (11.6 ± 3.4 vs. 14.9 ± 5.3 mmHg, P = 0.026). Full anticoagulation led to almost complete resolution of HALT in 13 patients with follow-up CTA. Conclusion Irrespective of the antiplatelet regimen, early HALT occurred in 10% of our patients undergoing transcatheter aortic S3 implantation. Early HALT is clinically inapparent and reversible by full anticoagulation.

Cite

CITATION STYLE

APA

Pache, G., Schoechlin, S., Blanke, P., Dorfs, S., Jander, N., Arepalli, C. D., … Ruile, P. (2016). Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves. European Heart Journal, 37(28), 2263–2271. https://doi.org/10.1093/eurheartj/ehv526

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free