Abstract
We investigated the flow field within a rigid-walled in vitro model of an end-to-side 45 degree anastomosis in an attempt to identify possible hemodynamic factors that may contribute to the pathogenesis of distal anastomotic intimal hyperplasia. A high-resolution photochromic tracer technique was used to visualize the flow in orthogonal planes and to determine the axial wall shear stress profiles for both steady and pulsatile flows over a range of physiologically relevant conditions. The flow field showed qualitative similarities to those seen in curved vessel: rapidly moving fluid from the graft section affects the bed of the host vessel, that is, the wall opposite the anastomosis, eventually advancing down the host vessel in a spiraling motion. A small mobile separation zone was noted at the toe of the anastomosis. Comparison of wall shear stress profiles with previously reported preferential sites for the development of intimal hyperplasia supported a low wall shear stress and/or flow separation pathogenesis hypothesis. One notable exception was the bed of the host artery that appeared to be subjected to a complex hemodynamic environment. (J VASC SURG 1990;12:747-53.) © 1990, Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter. All rights reserved.
Cite
CITATION STYLE
Ojha, M., Ethier, C. R., Johnston, K. W., & Cobbold, R. S. C. (1990). Steady and pulsatile flow fields in an end-to-side arterial anastomosis model. Journal of Vascular Surgery, 12(6), 747–753. https://doi.org/10.1067/mva.1990.24365
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.