Thermal-hydraulic modeling of the steady-state operating conditions of a fire-tube boiler

5Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

In this work, we are interested to simulate the thermal-hydraulic behavior of three-pass type fire-tube boiler. The plant is de signed to produce 4.5 tons per hour of saturated steam at 8 bar destined principally for heating applications. A calculation program is developed in order to simulate the boiler operation under several steady-state operating conditions. This program is based upon heat transfer laws between hot gases and the fire-tube internal walls. In the boiler com bustion chamber, the heat transfer has been simulated using the well-stirred furnace model. In the convection section, heat balance has been carried out to estimate the heat exchanges between the hot gases and the tube banks The obtained results are compared to the steady-state operating data of the considered plant. A comparative analysis shows that the calculation results are in good agreement with the boiler operating data. Further more, a sensitivity study has been carried out to assess the effects of input parameters, namely the fuel flow rate, air excess, ambient temperature, and operating pressure, upon the boiler ther mal performances.

Cite

CITATION STYLE

APA

Rahmani, A., & Dahia, A. (2009). Thermal-hydraulic modeling of the steady-state operating conditions of a fire-tube boiler. Nuclear Technology and Radiation Protection, 24(1), 29–37. https://doi.org/10.2298/NTRP0901029R

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free