A novel potentiometric biosensor for selective l-cysteine determination using l-cysteine-desulfhydrase producing Trichosporon jirovecii yeast cells coupled with sulfide electrode

29Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Trichosporon jirovecii yeast cells are used for the first time as a source of l-cysteine desulfhydrase enzyme (EC 4.4.1.1) and incorporated in a biosensor for determining l-cysteine. The cells are grown under cadmium stress conditions to increase the expression level of the enzyme. The intact cells are immobilized on the membrane of a solid-state Ag2S electrode to provide a simple l-cysteine responsive biosensor. Upon immersion of the sensor in l-cysteine containing solutions, l-cysteine undergoes enzymatic hydrolysis into pyruvate, ammonia and sulfide ion. The rate of sulfide ion formation is potentiometrically measured as a function of l-cysteine concentration. Under optimized conditions (phosphate buffer pH 7, temperature 37 ± 1 °C and actual weight of immobilized yeast cells 100 mg), a linear relationship between l-cysteine concentration and the initial rate of sulfide liberation (dE/dt) is obtained. The sensor response covers the concentration range of 0.2-150 mg L-1 (1.7-1250 μmol L-1) l-cysteine. Validation of the assay method according to the quality control/quality assurance standards (precision, accuracy, between-day variability, within-day reproducibility, range of measurements and lower limit of detection) reveals remarkable performance characteristics of the proposed biosensor. The sensor is satisfactorily utilized for determination of l-cysteine in some pharmaceutical formulations. The lower limit of detection is ∼1 μmol L-1 and the accuracy and precision of the method are 97.5% and ±1.1%, respectively. Structurally similar sulfur containing compounds such as glutathione, cystine, methionine, and d-cysteine do no interfere. © 2007 Elsevier B.V. All rights reserved.

Cite

CITATION STYLE

APA

Hassan, S. S. M., El-Baz, A. F., & Abd-Rabboh, H. S. M. (2007). A novel potentiometric biosensor for selective l-cysteine determination using l-cysteine-desulfhydrase producing Trichosporon jirovecii yeast cells coupled with sulfide electrode. Analytica Chimica Acta, 602(1), 108–113. https://doi.org/10.1016/j.aca.2007.09.007

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free