Concurrent evaluation of data quality, reliability and validity of the Australian/Canadian Osteoarthritis Hand Index and the Functional Index for Hand Osteoarthritis

47Citations
Citations of this article
59Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: Concurrent evaluation of data quality, internal consistency, test-retest reliability and validity of two patient-reported outcome measures (PROMs) for measuring functional impairment in hand OA (HOA); the Australian/Canadian Osteoarthritis Hand Index (AUSCAN; 15 items) and the Functional Index of HOA (FIHOA; 10 items). Methods: Patients from an HOA cohort [n = 128, mean age 68.6 (S.D. 5.8) years, 91% women] completed PROMs and performance measures during routine follow-up. One week later, a subsample (n = 40) reporting no change on an HOA-specific transition question contributed with test-retest data. Results: Both instruments had satisfactory levels of data quality, internal consistency, test-retest reliability and construct validity. The AUSCAN performed slightly better than the FIHOA relating to levels of missing data (0 vs 5%), floor effects, principal component analysis loadings (0.62-0.83 vs 0.52-0.83), item-total correlation (0.77-0.91 vs 0.45-0.76) and Cronbach's α (0.94-0.96 vs 0.90), respectively. AUSCAN items had slightly lower test-retest κ-values (0.29-0.77 vs FIHOA 0.41-0.77) and AUSCAN scales lower intraclass correlations (0.80-0.92 vs FIHOA 0.94). Correlations between the two instruments ranged from 0.58 to 0.88 for the AUSCAN scales of stiffness and physical function, respectively. AUSCAN physical function scale was generally slightly strongly correlated with the other PROMS and performance measures. Conclusion. The AUSCAN and the FIHOA are reliable and valid instruments suitable for measuring physical functioning in HOA. The FIHOA had higher test-retest reliability and is shorter, but the AUSCAN performed slightly better concerning data quality and construct validity. © The Author 2010. All rights reserved.

Cite

CITATION STYLE

APA

Moe, R. H., Garratt, A., Slatkowsky-Christensen, B., Maheu, E., Mowinckel, P., Kvien, T. K., … Uhlig, T. (2010). Concurrent evaluation of data quality, reliability and validity of the Australian/Canadian Osteoarthritis Hand Index and the Functional Index for Hand Osteoarthritis. Rheumatology, 49(12), 2327–2336. https://doi.org/10.1093/rheumatology/keq219

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free