Abstract
A high-strength bolt of a steel structure of a nuclear power plant failed and fell off. In order to determine the cause of the bolt's fracture, a series of tests such as macro inspection, physical and chemical performance test, and microscopic analysis of the fracture were carried out on the failed bolt. The results show that the cause of bolt fracture is hydrogen embrittlement. Hydrogen infiltrated into the bolt during the phosphating process and the corrosion process during use, and then hydrogen continued to accumulate eventually causing hydrogen embrittlement fracture. Dehydrogenation treatment should be performed immediately after the phosphorylation treatment, and the anti-corrosion method of the bolt should be optimized, which is an effective measure to prevent the hydrogen embrittlement of high strength bolts.
Author supplied keywords
Cite
CITATION STYLE
Lai, Y., Ma, Q., Zuo, D., Zhang, G., & Zhang, K. L. Z. (2021). Mechanical Properties and Fracture Analysis of High Strength Bolts in Nuclear Power Plant. In Journal of Physics: Conference Series (Vol. 2083). IOP Publishing Ltd. https://doi.org/10.1088/1742-6596/2083/2/022064