Investigation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput liquid chromatography/tandem mass spectrometry assays

57Citations
Citations of this article
41Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Triple quadrupole mass spectrometers, when operated in multiple reaction monitoring (MRM) mode, offer a unique combination of sensitivity, specificity, and dynamic range. Consequently, the triple quadrupole is the workhorse for high-throughput quantitation within the pharmaceutical industry. However, in the past, the unit mass resolution of quadrupole instruments has been a limitation when interference from matrix or metabolites cannot be eliminated. With recent advances in instrument design, triple quadrupole instruments now afford mass resolution of less than 0.1 Dalton (Da) full width at half maximum (FWHM). This paper describes the evaluation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput bioanalysis with emphasis on comparison of selectivity, sensitivity, dynamic range, precision, accuracy, and stability under both unit mass (1 Da FWHM) and enhanced (≤0.1 Da FWHM) resolution. The advantage of enhanced resolution was demonstrated in the case of mometasone with polypropylene glycol (PPG) interference. At unit mass resolution, the transmitted precursor ion from the first quadrupole contained not only protonated molecules from mometasone, but also PPG interference. At enhanced resolution only selected mometasone peaks were transmitted, and no interference from PPG was detected. Sensitivity of the instrument was demonstrated with 10 femtograms of descarboethoxyloratadine injected on-column, for which a signal-to-noise (S/N) ratio of 24 was obtained for MRM chromatograms at both unit and enhanced resolution. Absolute signals obtained at enhanced resolution were about one-third those obtained at unit mass resolution. However, S/N was maintained at enhanced resolution due to the proportional decrease in noise level. Finally, the stability of the instrument operating at enhanced resolution was demonstrated during an overnight 17h period that was used to validate a liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay for the quantitation of loratadine and descarboethoxyloratadine in human plasma. Assay performances (dynamic range, correlation coefficients for standard curves, precision and accuracy for QC samples) under unit and enhanced resolution were both within current pharmaceutical and regulatory guidelines demonstrating the stability of the mass spectrometer operating at enhanced resolution for typical bioanalytical high-throughput applications. Copyright © 2002 John Wiley & Sons, Ltd.

Cite

CITATION STYLE

APA

Yang, L., Amad, M., Winnik, W. M., Schoen, A. E., Schweingruber, H., Mylchreest, I., & Rudewicz, P. J. (2002). Investigation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput liquid chromatography/tandem mass spectrometry assays. Rapid Communications in Mass Spectrometry, 16(21), 2060–2066. https://doi.org/10.1002/rcm.824

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free