Influence of light source on the sensitivity of a Polarization Maintaining Fiber Loop Mirror vibration sensor

2Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Wavelength or light intensity demodulation method for a polarization maintaining fiber loop mirror (PM-FLM) sensor is not only expensive but also unsuitable for vibration monitoring. This paper studies the voltage demodulation principle and explores theoretically the influence of light source on the sensitivity. Then a PM-FLM sensor is applied to vibration monitoring. A low-power narrow-band light source reflected from FBG and a high-power laser light source are used respectively as input. The time domain voltage signals of vibration from a photo-detector are collected by a data acquisition card and converted via a fast Fourier transform algorithm. The experimental result shows that a PM-FLM sensor using a high-power narrow-band light source as input has a higher sensitivity to vibration than the one using a low-power narrow-band light source. In practical application, we can choose a high-power narrow-band light source as input to improve the sensitivity to vibration.

Cite

CITATION STYLE

APA

Jiang, Y., Yu, M., Zhang, M., & Lu, J. (2020). Influence of light source on the sensitivity of a Polarization Maintaining Fiber Loop Mirror vibration sensor. Journal of Low Frequency Noise Vibration and Active Control, 39(2), 327–334. https://doi.org/10.1177/1461348419848886