The diagnostic performance of the length of tumor capsular contact on mri for detecting prostate cancer extraprostatic extension: A systematic review and meta-analysis

42Citations
Citations of this article
31Readers
Mendeley users who have this article in their library.

Abstract

Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73–0.83) and 0.67 (95% CI 0.60–0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77–0.84). Substantial heterogeneity was present among the included studies according to Cochran’s Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers’ experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14–0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

Cite

CITATION STYLE

APA

Kim, T. H., Woo, S., Han, S., Suh, C. H., Ghafoor, S., Hricak, H., & Vargas, H. A. (2020). The diagnostic performance of the length of tumor capsular contact on mri for detecting prostate cancer extraprostatic extension: A systematic review and meta-analysis. Korean Journal of Radiology, 21(6), 684–694. https://doi.org/10.3348/kjr.2019.0842

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free