A validated UPLC-MS/MS method for flibanserin in plasma and its pharmacokinetic interaction with bosentan in rats

N/ACitations
Citations of this article
9Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Aim: The purpose of this study was development, validation and application of ultra-performance liquid chromatography (UPLC)-ESI-MS/MS method for quantitation of flibanserin in plasma samples.Method & results: After extraction of analyte from plasma by diethyl ether, separation was performed on UPLC C18 column using mobile phase composition of 10 mM ammonium formate-acetonitrile (30:70, v/v) by isocratic elution of 0.3 ml/min. The multiple reaction monitoring transitions of m/z 391.13 → 161.04 and 384.20 → 253.06 were used for detection of analyte and internal standard (quetiapine), respectively. The calibration curves were linear (r ≥ 0.995) between 0.22 and 555 ng/ml concentration and all validation results were within the acceptable range as per US FDA guidelines. Conclusion: The assay procedure was fully validated and successfully applied in pharmacokinetic interaction study of flibanserin with bosentan in rats.

Cite

CITATION STYLE

APA

Iqbal, M., Ezzeldin, E., Rezk, N. L., Bajrai, A. A., & Al-Rashood, K. A. (2018). A validated UPLC-MS/MS method for flibanserin in plasma and its pharmacokinetic interaction with bosentan in rats. Bioanalysis, 10(14), 1087–1097. https://doi.org/10.4155/bio-2018-0065