Performance of antigen testing for diagnosis of COVID-19: a direct comparison of a lateral flow device to nucleic acid amplification based tests

41Citations
Citations of this article
71Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: The gold standard for diagnosing an infection with SARS-CoV-2 is detection of viral RNA by nucleic acid amplification techniques. Test capacities, however, are limited. Therefore, numerous easy-to-use rapid antigen tests based on lateral flow technology have been developed. Manufacturer-reported performance data seem convincing, but real-world data are missing. Methods: We retrospectively analysed all prospectively collected antigen tests results performed between 23.06.2020 and 26.11.2020, generated by non-laboratory personnel at the point-of-care from oro- or nasopharyngeal swab samples at the University Hospital Augsburg and compared them to concomitantly (within 24 h.) generated results from molecular tests. Results: For a total of 3630 antigen tests, 3110 NAAT results were available. Overall, sensitivity, specificity, NPV and PPV of antigen testing were 59.4%, 99.0%, 98.7% and 64.8%, respectively. Sensitivity and PPV were lower in asymptomatic patients (47.6% and 44.4%, respectively) and only slightly higher in patients with clinical symptoms (66.7% and 85.0%, respectively). Some samples with very low Ct-values (minimum Ct 13) were not detected by antigen testing. 31 false positive results occurred. ROC curve analysis showed that reducing the COI cut-off from 1, as suggested by the manufacturer, to 0.9 is optimal, albeit with an AUC of only 0.66. Conclusion: In real life, performance of lateral-flow-based antigen tests are well below the manufacturer's specifications, irrespective of patient’s symptoms. Their use for detection of individual patients infected with SARS-CoV2 should be discouraged. This does not preclude their usefulness in large-scale screening programs to reduce transmission events on a population-wide scale.

Cite

CITATION STYLE

APA

Kahn, M., Schuierer, L., Bartenschlager, C., Zellmer, S., Frey, R., Freitag, M., … Römmele, C. (2021). Performance of antigen testing for diagnosis of COVID-19: a direct comparison of a lateral flow device to nucleic acid amplification based tests. BMC Infectious Diseases, 21(1). https://doi.org/10.1186/s12879-021-06524-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free