Abstract
SiPM-based readouts are becoming the standard for light detection in particle detectors given their superior resolution and ease of use with respect to vacuum tube photo-multipliers. However, the contributions of noise detection such as the dark rate, cross-talk, and after-pulsing (AP) may significantly impact their performance. In this work, we present the development of highly reflective single-phase argon chambers capable of displaying light yields up to 32 photo-electrons per keV, with approximately 12 being primary photo-electrons generated by the argon scintillation, while the rest are accounted by optical cross-talk. Furthermore, the presence of compound processes results in a generalized Fano factor larger than 2 already at an over-voltage of 5 V. Finally, we present a parametrization of the optical cross-talk for the FBK NUV-HD-Cryo SiPMs at 87 K that can be extended to future detectors with tailored optical simulations.
Author supplied keywords
Cite
CITATION STYLE
Boulay, M. G., Camillo, V., Canci, N., Choudhary, S., Consiglio, L., Flammini, A., … Sanfilippo, S. (2023). SiPM cross-talk in liquid argon detectors. Frontiers in Physics, 11. https://doi.org/10.3389/fphy.2023.1181400