Fire performance of bolted connections in laminated veneer lumber

32Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This paper describes an investigation into the fire performance of bolted tensile connections in laminated veneer lumber (LVL) made from radiata pine. The capacity of the bolted connections depends on the embedment strength of the wood and on the yield moment of the bolts. The purpose of the research was to develop a prediction method for the time to failure of the connections when exposed to fire. An experimental investigation was carried out on the axial tensile strength of three types of bolted connections that utilized either wood or steel splice plates. Some specimens were tested at ambient temperatures while similar specimens were tested in fire conditions with a constant applied load. In addition, single-bolted connections were tested under constant elevated temperature conditions to determine the embedment strength of the LVL. Connections with no steel plates, or with steel plates slotted between the timber members, performed better than those with exposed steel. A simplified design approach is proposed, using an extension of the Johansen formulae, such that the embedment strength of the LVL depends on the temperature in the bolt. Copyright © 2009 John Wiley & Sons, Ltd.

Cite

CITATION STYLE

APA

Moss, P. J., Buchanan, A. H., Fragiacomo, M., Lau, R. H., & Chuo, T. (2009). Fire performance of bolted connections in laminated veneer lumber. Fire and Materials, 33(5), 223–243. https://doi.org/10.1002/fam.999

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free