Energy distribution of X-rays produced by meter-long negative discharges in air

10Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

The energy deposited from X-rays generated by 1 m long laboratory sparks in air created by 950 kV negative lightning impulses on scintillated detectors was measured. Assuming the X-ray energy detected in such sparks results from the accumulation of multiple photons at the detector having a certain energy distribution, an experiment was designed in such a way to characterize their distribution parameters. The detector was screened by a copper shield, and eight series of fifteen impulses were applied by stepwise increasing the copper shield thickness. The average deposited energy was calculated in each series and compared with the results from a model consisting of the attenuation of photons along their path and probable photon distributions. The results show that the energy distribution of X-ray bursts can be approximated by a bremsstrahlung spectrum of photons, having a maximum energy of 200 keV to 250 keV and a mean photon energy around 52 keV to 55 keV.

Cite

CITATION STYLE

APA

Hettiarachchi, P., Cooray, V., Rahman, M., & Dwyer, J. (2017). Energy distribution of X-rays produced by meter-long negative discharges in air. Atmosphere, 8(12). https://doi.org/10.3390/atmos8120244

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free