Comparative accuracy of the InBios scrub typhus detect IgM rapid test for the detection of IgM antibodies by using conventional serology

38Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This study investigated the comparative accuracy of a recombinant 56-kDa type-specific antigen-based rapid diagnostic test (RDT) for scrub typhus for the detection of IgM antibodies by using conventional serology in well-characterized serum samples from undifferentiated febrile illness patients. The RDT showed high specificity and promising comparative accuracy, with 82% sensitivity and 98% specificity for samples defined positive at an IgM indirect immunofluorescence assay positivity cutoff titer of ≥1:1,600 versus 92% and 95% at ≥1:6,400, respectively.

Cite

CITATION STYLE

APA

Kingston, H. W. F., Blacksell, S. D., Tanganuchitcharnchai, A., Laongnualpanich, A., Basnyat, B., Day, N. P. J., & Paris, D. H. (2015). Comparative accuracy of the InBios scrub typhus detect IgM rapid test for the detection of IgM antibodies by using conventional serology. Clinical and Vaccine Immunology, 22(10), 1130–1132. https://doi.org/10.1128/CVI.00390-15