Application of an original improved U-pillow in patients with prone position ventilation: A comparative retrospective observational study

0Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Patients in the prone position in the intensive care unit are at risk of facial skin failure, a concern that has traditionally been managed through frequent repositioning, often necessitating considerable effort from healthcare practitioners. This study aims to evaluate the effectiveness of an original improved U-shaped pillows in preventing pressure injuries to the head and face of patients undergoing prone ventilation. A retrospective analysis was conducted on data from 61 patients who underwent prone positioning ventilation. The study group consisted of 31 patients who used the improved U-shaped pillow, which features 7 independent air chambers designed for dynamic segmental pressure regulation. The control group was composed of 30 patients who underwent decompression using traditional integrated U-shaped sponge pillows, which lack pressure-adjustment capabilities. There were no significant differences between the 2 groups at baseline. While the intergroup difference in facial pressure injury incidence was not statistically significant (6.5% vs 23.3%, P = .081) and no significant benefit was detected in the univariate analysis (P = .080), a significant advantage of the new pillow emerged after adjusting for potential confounders. In the multivariate regression analysis, the study group demonstrated a significantly reduced incidence of facial pressure injuries compared to the control group (P = .048). A comparison of the average number of head position changes per hour between the 2 patient groups during prone positioning indicated that the study group demonstrated significantly better performance than the control group. This difference was statistically significant (0.55 ± 0.10 vs 0.68 ± 0.15, P

Cite

CITATION STYLE

APA

Wang, X., Fu, L., Ye, Y., Chen, H., Wang, Y., Huang, B., … Jian, C. (2026). Application of an original improved U-pillow in patients with prone position ventilation: A comparative retrospective observational study. Medicine (United States), 105(15), e48204. https://doi.org/10.1097/MD.0000000000048204

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free