Improvement of Surgical View and Working Space at the Lower Pole by Three-Dimensional Exoscope-Assisted Coblation Tonsillectomy: A Case Series

0Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

Advantages of hot devices for tonsillectomy, represented by coblation, have been highlighted in recent years. During hot technique tonsillectomy it is important to identify and coagulate the vessels of the tonsillar capsule, especially at the lower pole of the tonsil. Hot technique tonsillectomy under microscope or endoscope has therefore been recommended to achieve accurate identification of the microstructure of the surgical field. We have applied ORBEYE, a three-dimensional surgical exoscope system, to coblation tonsillectomy. Advantages of using ORBEYE include high definition and high magnification images, and flexibility of camera position and angle. This means there is an improved surgical view and working space, particularly at the lower pole during performance of coblation tonsillectomy. Here, we demonstrate that ORBEYE can be an effective surgical instrument in coblation tonsillectomy.

Author supplied keywords

Cite

CITATION STYLE

APA

Murakami, D., Hijiya, M., Iyo, T., Sugita, G., Hayata, S., Kono, M., & Hotomi, M. (2023). Improvement of Surgical View and Working Space at the Lower Pole by Three-Dimensional Exoscope-Assisted Coblation Tonsillectomy: A Case Series. Medicina (Lithuania), 59(2). https://doi.org/10.3390/medicina59020259