Long-term angiographic follow-up after successful repeat balloon angioplasty for in-stent restenosis

3Citations
Citations of this article
4Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Coronary stent implantation is associated with improved angiographic short-term and mid-term clinical outcome. However, restenosis rate still remains between 20 and 30%. Hypothesis: The purpose of the study, performed as a prospective angiographic follow-up to detect restenosis, was to evaluate the immediate and the 6-month angiographic results of repeat balloon angioplasty for in-stent restenosis. Methods: From April 1996 to September 1997, 335 stenting procedures performed in 327 patients underwent prospectively 6-month control angiography. Of the 96 lesions that showed in-stent restenosis (> 50% diameter stenosis) (29%), 72 underwent balloon angioplasty. Results: The primary success rate was 100%. Follow-up angiogram at a mean of 6.9 ± 2.4 months was obtained in 54 patients. Recurrent restenosis was observed in 24 of the 55 stents (44%). Repeat intervention for diffuse and body location in-stent restenosis before repeat intervention was associated with significantly higher rates of recurrent restenosis (p < 0.001 and p < 0.05, respectively). Of the 19 patients who underwent further balloon angioplasty (100% success rate), coronary angiography was performed in 18 (95%) at a mean of 8.2 ± 2.0 months and showed recurrent restenosis in 12 patients (67%). Further repeat intervention for diffuse and severe in-stent restenosis before the second repeat intervention was associated with significantly higher rates of further recurrent restenosis (p < 0.05 and p < 0.005, respectively). Conclusions: Although balloon angioplasty can be safely, successfully, and repeatedly performed after stent restenosis, it carries a progressively high recurrence of angiographic restenosis rate during repeat 6-month follow-ups. The subgroup of patients with diffuse, severe, and/or body location in-stent restenosis proved to be at higher risk of recurrent restenosis.

Cite

CITATION STYLE

APA

Galassi, A. R., Foti, R., Azzarelli, S., Condorelli, G., Coco, G., Ragusa, A., … Giuffrida, G. (2001). Long-term angiographic follow-up after successful repeat balloon angioplasty for in-stent restenosis. Clinical Cardiology, 24(4), 334–340. https://doi.org/10.1002/clc.4960240415

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free