Radiographic and Patient-Reported Outcomes of a Low-Cost Modified Lapidus Bunion Correction Technique

0Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The modified Lapidus (ML) is a powerful procedure for correction of hallux valgus (HV) with emerging techniques. Studies considering patient-reported outcomes, radiographic measures, complications, and implant costs are currently limited. Methods: Retrospective cohort with prospectively collected Patient Reported Outcome Information System Physical Function (PROMIS-PF) Computerized Adaptive Test (CAT) scores, radiographic parameters (intermetatarsal angle, IMA; hallux valgus angle, HVA; and tibial sesamoid position, TSP), complications, and total operative time and implant costs were reviewed from 2014 to 2019. Results: Seventy-three feet (68 patients) underwent bunion correction by ML with lag-screw fixation. Median age was 55.8 years (IQR 45.6, 53.9), 4 of 73 (5.5%) were male, 11 of 73 (15.1%) were smokers, and 15 of 73 (20.6%) were diabetic (median HbA1c 6.4% [IQR 6.0, 7.4], none insulin dependent, 5 of 15 with neuropathy). Complications included 6 of 73 (8.2%) wound issues resolved with topical or oral treatment, 9 of 73 (12.3%) painful or broken hardware requiring hardware removal. Two of 73 (2.7%) had persistent pain despite union. One of 73 (1.4%) was overcorrected and required first MTP arthrodesis. Of 3 nonunions (2.7%), 1 resolved with corrected hypothyroidism, 1 was asymptomatic and required no treatment, 1 had a hallux valgus recurrence and sought revision surgery elsewhere. Preoperative radiographic angles were HVA 35 degrees, IMA 14 degrees which improved at final postoperative follow up to HVA 10 degrees, IMA 6 degrees. Tibial sesamoid position improved from 6.05 ± 1.00 to 2.22 ± 1.38. Thirty-two patients had preoperative and 42 had 1-year postoperative outcomes. PROMIS-PF (51% collection rate) was 43 (IQR 37,52) preoperatively, 37 (31, 39) at 6 weeks, 46 (42, 51) at 3 months, and 49 (41, 53) at >360 days postoperatively. The drop in PROMIS-PF between preoperative and 6 weeks and the rise from 6 weeks to 3 months were statistically significant. Pre- and postoperative PROMIS-PF scores were not significantly different. Implant cost averaged US$146. Discussion/Conclusion: We report low complication rates and costs with high patient postoperative functional and radiographic outcomes. PROMIS-PF decreased acutely postoperatively but recovered and maintained high levels by 3 months postoperatively. Level of Evidence: Level IV, case series.

Cite

CITATION STYLE

APA

Paranjape, C. S., Zhang, J., Lalli, T., Lin, F. C., & Tennant, J. N. (2023). Radiographic and Patient-Reported Outcomes of a Low-Cost Modified Lapidus Bunion Correction Technique. Foot and Ankle Orthopaedics, 8(3). https://doi.org/10.1177/24730114231200482

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free