Conformal Swallowing Accelerometry: Reimagining the Acquisition and Characterization of Swallowing Mechano-Acoustic Signals

0Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.

Abstract

Highlights: This study utilized a conformal array of accelerometers to revisit the core assumptions of swallowing signal reproducibility and symmetry that justify the single-point approach to cervical auscultation and swallowing accelerometry. What are the main findings? Similar to previous studies, swallowing mechano-acoustic signals were found to be grossly reproducible over repeated trials. In contrast to the longstanding assumption, our data suggested grossly asymmetric peak intensities across the two sides of the neck. What is the implication of the main finding? Multi-channel swallowing accelerometry potentially allows clinicians and researchers to move beyond the traditional practice, paving the way for the design of advanced wearable sensors capable of evaluating and monitoring swallowing mechanics. (1) Background: Non-invasive instrumental measurement of swallowing acoustic signals has rested upon the assumptions of signal symmetry and reproducibility along the cervical region and has hence taken the form of single-point acquisition on optimal sites. This study aimed to (i) revisit such assumptions by adopting a conformal array of accelerometers, and hence (ii) lay the foundation for the future design of swallowing accelerometry. (2) Methods: Thirteen young healthy individuals, including eight females (mean age ± SD = 24.38 ± 0.92) and five males (mean age ± SD = 24 ± 3.74), were recruited. Swallowing mechano-acoustic signals of repeated swallowing trials were captured using conformal swallowing accelerometry. The peak intensities and frequencies as well as their respective peak times were extracted from six symmetrical and vertically aligned sites. (3) Results: Three-way ANOVAs with repeated measures suggested differences across trials and channels for both peak intensity and frequency. The additional interaction of bolus volume and repeated trials with a small effect size was also indicated in peak frequency. Intra-personal variability was indicated by coefficients of variance of the peak intensity and frequency of higher than 20%, with values varying within the 95% limits of agreement of at least 10 m/s2 and 100 Hz, respectively. However, intra-trial comparisons of contra-lateral peak intensity and frequency also revealed a high degree of variability, with the 95% limits of agreement up to 12 m/s2 and 240 Hz, respectively. On the other hand, the time points of intra-trial peak intensity and frequency showed a high degree agreement, suggesting the possibility of signal asymmetry. (4) Conclusions: The current findings not only confirmed the previous proposal of intra-personal variability but also demonstrated preliminary counterevidence to the longstanding assumption of signal symmetry. Alternatively, the use of conformal swallowing accelerometry is a promising option for the future design and implementation of non-invasive swallowing mechano-acoustic measurements.

Cite

CITATION STYLE

APA

Lam, W. Y. S., Kwong, E., Leung, R. C. K., Lee, C. H., Rai, S., & Lui, L. K. (2025). Conformal Swallowing Accelerometry: Reimagining the Acquisition and Characterization of Swallowing Mechano-Acoustic Signals. Sensors, 25(23). https://doi.org/10.3390/s25237396

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free