Conserving the coherence and uniformity of third-generation synchrotron radiation beams: The case of ID19, a 'long' beamline at the ESRF

27Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

The lateral coherence length is of the order of 100 μm at the 'long' (145 m) ID19 beamline of the ESRF, which is mainly devoted to imaging. Most of the optical elements located along the X-ray path can thus act as 'phase objects', and lead to spurious contrast and/or to coherence degradation, which shows up as an enhanced effective angular size of the source. Both the spurious contrast and the coherence degradation are detrimental for the images (diffraction topographs, tomographs, phase-contrast images) produced at this beamline. The problems identified and the way they were solved during the commissioning of ID19 are reported. More particularly, the role of the protection foils located in the front end, the beryllium windows, the filters and the monochromator defects (scratches, dust, small vibrations) is discussed.

Cite

CITATION STYLE

APA

Espeso, J. I., Cloetens, P., Baruchel, J., Härtwig, J., Mairs, T., Biasci, J. C., … Schlenker, M. (1998). Conserving the coherence and uniformity of third-generation synchrotron radiation beams: The case of ID19, a “long” beamline at the ESRF. Journal of Synchrotron Radiation, 5(5), 1243–1249. https://doi.org/10.1107/S0909049598002271