R-wave sensing in an implantable cardiac monitor without ECG-based preimplant mapping: Results from a multicenter clinical trial

24Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction Reducing the form factor of an implantable cardiac monitor (ICM) may simplify device implant. This study evaluated R-wave sensing at a range of electrode distances and a preferred device implant location without mapping. Methods Patients scheduled for a Medtronic Reveal® ICM implant (Medtronic Inc., Minneapolis, MN, USA) underwent a preimplant pocket recording using a diagnostic recording catheter. The ICM implant location was left to the discretion of the implanting physician, but a "recommended" position spanned the V2-V3 electrocardiogram electrode location in an oblique 45° angle. R-wave amplitudes were analyzed from ICM follow-up. Results Seventeen of 41 subjects (15 male, age 57 ± 16 years) had the maximum surface-filtered R-wave at the recommended location. Fourteen patients underwent diagnostic recording across the range of electrode spacing. There was a strong correlation between the R-wave amplitude and electrode distance (r 2 = 0.97, P < 0.001) with an increase of 29 μV per 2.5 mm. Comparing normalized R-wave distributions between the recommended ICM implant group (Group 1, n = 19) and the remaining patients (Group 2, n = 7), the proportion of ICM R-wave counts of amplitude 0.25-1.2 mV was higher (79% vs 46%, P < 0.05). Of 17 patients in Group 1 who had ≥1-month ICM follow-up (79 ± 45 days), no sensing-related false arrhythmia detection was found in 16 (93%) patients. Conclusions The subcutaneous R-wave amplitude correlates with electrode spacing in the implant zone of ICM patients. Implant locations at the V2-V3 position at a 45° angle offer an adequate R wave for sensing. Preimplant mapping to achieve acceptable R-wave amplitude may not be necessary. ©2013 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc.

Cite

CITATION STYLE

APA

Krahn, A. D., Pickett, R. A., Sakaguchi, S., Shaik, N., Cao, J., Norman, H. S., & Guerrero, P. (2014). R-wave sensing in an implantable cardiac monitor without ECG-based preimplant mapping: Results from a multicenter clinical trial. PACE - Pacing and Clinical Electrophysiology, 37(4), 505–511. https://doi.org/10.1111/pace.12303

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free