Development of immunoassays for biomonitoring of hexamethylene diisocyanate exposure

16Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

Hexamethylene diisocyanate (HDI) is used widely to manufacture polyurethanes for paints and coatings. It is an irritant and a chemical asthmagen. The U.S. Occupational Safety and Health Administration time-weighted average permissible exposure limit is 5 ppb and the ceiling limit is 20 ppb. We sought to develop a sensitive and specific immuno-bioassay to supplement workplace air monitoring and detect recent HDI exposure. For this, we produced rabbit antiserum to HDI-adducted keyhole limpet hemocyanin (HDI-KLH). The specificity of the antiserum was demonstrated by its reaction with a variety of HDI-conjugated proteins and the absence of reactions with conjugates of other diisocyanates, namely toluence diisocyanate and diphenyl methylene diisocyanate. Four immunoassays were developed and compared for their ability to detect decreasing quantities of HDI-adducted human serum albumin (HSA) containing 2 mol HDI adduct per mol HSA (HDI2-HSA) as determined by matrix-assisted laser desorption time-of-flight (MALDI-TOF) mass spectrometry. The sensitivities of some of the assays are within the range (0.82-45 nM) of current analytic methods. A Western analysis procedure has a sensitivity of 600 nM HDI adduct on HSA. ELISA inhibition assay, in which microtiter plates are coated with the HDI2-HSA antigen, has a sensitivity of 300 nM HDI adduct. An immunoblot assay has a sensitivity of 9 nM HDI adduct. The most sensitive bioassay (1.8 nM HDI adduct) is a three-antibody sandwich ELISA in which wells of microtiter plates are coated with the IgG fraction of the anti-HDI-KLH antisera. Compared with analytic methods for HDI biomonitoring, the immunoassays are faster and less costly and accommodate numerous samples simultaneously. The assays have the potential to affect industrial biomonitoring programs significantly.

Cite

CITATION STYLE

APA

Lemus, R., Lukinskeine, L., Bier, M. E., Wisnewski, A. V., Redlich, C. A., & Karol, M. H. (2001). Development of immunoassays for biomonitoring of hexamethylene diisocyanate exposure. Environmental Health Perspectives, 109(11), 1103–1108. https://doi.org/10.1289/ehp.011091103

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free