PD11-04 CONVENTIONAL VERSUS COMPUTER ASSISTED STEREOSCOPIC ULTRASOUND NEEDLE GUIDANCE FOR RENAL ACCESS: A RANDOMIZED BENCH-TOP CROSSOVER TRIAL

  • Thomas A
  • Thomas J
  • Keheila M
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.
Get full text

Abstract

INTRODUCTION AND OBJECTIVES: During urologic surgery, ultrasound (US) is an established method for needle guidance, but difficulty in visualizing the needle trajectory may add technical complexity to the procedure. Needle guidance systems may simplify these procedures. The purpose of this randomized bench-top crossover trial was to compare conventional ultrasound and a computer assisted stereoscopic needle guidance system for obtaining renal access and mass biopsy. METHODS: Subjects were randomly assigned to target one structure in either a renal access or mass biopsy phantom using conventional or computer assisted US guidance (figure 1) in two crossover trials. Recorded outcomes included time to hit the designated target, number of successful trials, number of punctures, and number of course corrections. Participant demographics and opinions of the two ultrasound modalities were also obtained. Statistical analysis was performed using student t-test for numerical variables and the chisquare test for categorical variables. P value 0.05 was considered significant. RESULTS: Of the 71 subjects enrolled in this study, 11 were attending physicians, 27 were residents, and 32 were medical students. The computer assisted system significantly shortened the access time between skin puncture and target contact compared to conventional US (79.4 vs. 51.1 s; p=0.009) respectively. Number of needle course corrections during computer assisted trials was significantly decreased compared to conventional US (0.48 vs. 2.53; p<0.001). There was no significant difference in the number of successful punctures between conventional US and computer assisted trials (1.90 vs. 1.71; p=0.236) respectively. Novice subjects were significantly faster with computer assisted US needle guidance (70 sec vs. 107 sec; p<0.001), while experienced ultra-sonographers trended towards faster overall performance with conventional US needle guidance (91 sec vs. 126 sec; p=0.052). Seventy-three percent of subjects preferred the computer assisted system over conventional ultrasound. CONCLUSIONS: A computer assisted system has potential for improving patient safety during renal access and mass biopsy by reducing needle access time and course corrections, as well as making ultrasound guidance more available to a wider urologic audience. (Figure Presented).

Cite

CITATION STYLE

APA

Thomas, A., Thomas, J., Keheila, M., Mattison, B., West, B., Ruckle, D., … Baldwin, D. D. (2017). PD11-04 CONVENTIONAL VERSUS COMPUTER ASSISTED STEREOSCOPIC ULTRASOUND NEEDLE GUIDANCE FOR RENAL ACCESS: A RANDOMIZED BENCH-TOP CROSSOVER TRIAL. Journal of Urology, 197(4S). https://doi.org/10.1016/j.juro.2017.02.580

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free