Abstract
Purpose: This study focused on clarifying the durability of bioprosthetic valves in current practice. Methods: A total of 238 consecutive patients who underwent aortic valve replacement at a single institution from 2011 to 2020 were reviewed. We evaluated valve-related outcomes such as structural valve deterioration (SVD), especially in dialysis patients who received bioprosthetic valve. Results: Among the tissue valves implanted in 212 patients, 5 SVDs were recorded and 3 valves were replaced. All early valve failures occurred in relatively young dialysis patients and were recorded 3 to 5 years after the initial operation. Freedom from SVD at 6 years was 49.9% in patients on dialysis, compared with 100% in non-dialysis patients. Predic-tors of better survival in dialysis patients were better preoperative functional class and larger prosthetic valve size. Conclusions: The durability of bioprosthetic valves in the aortic position was suboptimal in dialysis patients. Mechanical valves can be an option for young, healthy dialysis patients with a large aortic valve annulus.
Author supplied keywords
Cite
CITATION STYLE
Uzuka, T., Nakamura, M., Sugiyama, H., Kondo, M., & Sakata, J. (2022). Durability of Bioprosthetic Valves in Patients on Dialysis. Annals of Thoracic and Cardiovascular Surgery, 28(5), 334–341. https://doi.org/10.5761/atcs.oa.21-00093