Abstract

Background: Most patients with type 1 diabetes do not achieve their glycemic targets. We aimed to assess the efficacy of glucoseresponsive insulin and glucagon closed-loop delivery for controlling glucose levels in adults with type 1 diabetes. Methods: We conducted a randomized crossover trial involving 15 adults with type 1 diabetes, comparing standard insulin-pump therapy with dual-hormone, closed-loop delivery. Patients were admitted twice to a clinical research facility and received, in random order, both treatments. Each 15-hour visit (from 1600 to 0700) included an evening exercise session, followed by a medium-sized meal, a bedtime snack and an overnight stay. During visits that involved closed-loop delivery, basal insulin and glucagon miniboluses were delivered according to recommendations based on glucose sensor readings and a predictive dosing algorithm at 10-minute intervals. During visits involving standard insulin-pump therapy (control visits), patients used conventional treatment. Results: Dual-hormone closed-loop delivery increased the percentage of time for which patients' plasma glucose levels were in the target range (median 70.7% [interquartile range (IQR) 46.1%-88.4%] for closed-loop delivery v. 57.3% [IQR 25.2%-71.8%]for control, p = 0.003) and decreased the percentage of time for which plasma glucose levels were in the low range (bottom of target range [< 4.0 mmol/L], 0.0% [IQR 0.0%-3.0%] for closed-loop delivery v. 10.2% [IQR 0.0%-13.0%] for control, p = 0.01; hypoglycemia threshold [< 3.3 mmol/L], 0.0% [IQR 0.0%-0.0%] for closed-loop delivery v. 2.8% [IQR 0.0%-5.9%] for control, p = 0.006). Eight participants (53%) had at least 1 hypoglycemic event (plasma glucose < 3.0mmol/L) during standard treatment, compared with just 1 participant (7%) during closed-loop treatment (p = 0.02). Interpretation: Dual-hormone, closed-loop delivery guided by advanced algorithms improved short-term glucose control and reduced the risk of hypoglycemia in a group of 15 adults with type 1 diabetes. © 2013 Canadian Medical Association or its licensors.

Cite

CITATION STYLE

APA

Haidar, A., Legault, L., Dallaire, M., Alkhateeb, A., Coriati, A., Messier, V., … Rabasa-Lhoret, R. (2013). Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: A randomized crossover controlled trial. CMAJ. Canadian Medical Association Journal, 185(4), 297–305. https://doi.org/10.1503/cmaj.121265

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free