Inverse planning with constraints to generate smoothed intensity- modulated beams

79Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Highly conformal dose distributions can be generated by intensity- modulated radiotherapy. Intensity-modulated beams (IMBs) are generally determined by inverse-planning techniques designed to maximize conformality. Usually such techniques apply no constraints on the form of the IMBs which may then develop fine-scale modulation. In this paper we present a technique for generating smoother IMBs, which yields a dose distribution almost identical to that without the constraint on the form of the IMBs. The method applies various filters successively at intervals throughout the iterative inverse planning. It is shown that the IMBs so determined using a simple median window filter have desirable properties in terms of increasing the efficiency of delivery by the dynamic multileaf collimator method and may be 'more like conventional beams' than unconstrained, highly modulated IMBs.

Cite

CITATION STYLE

APA

Webb, S., Convery, D. J., & Evans, P. M. (1998). Inverse planning with constraints to generate smoothed intensity- modulated beams. Physics in Medicine and Biology, 43(10), 2785–2794. https://doi.org/10.1088/0031-9155/43/10/008