Mechanical properties of high-strength fiber reinforced concrete

187Citations
Citations of this article
55Readers
Mendeley users who have this article in their library.

Abstract

A total of 504 concrete specimens are tested to study the effect of including hooked-end steel fiber reinforcement on the mechanical properties of high-strength fiber reinforced concrete. Fiber content ranges from zero to 1.5 percent by volume and the concrete matrix compressive strength is about 94.0 MPa (13,500 psi). The influence of fiber content on the compressive strength, modulus of rupture, toughness, and splitting tensile strength is presented. Addition of 1.5 percent by volume of hooked-end steel fibers resulted in a small increased (4.6 percent) in the compression strength while the modulus of rupture and the splitting tensile strength increased by 67.0 and 159.8 percent, respectively.

Cite

CITATION STYLE

APA

Wafa, F. F., & Ashour, S. A. (1992). Mechanical properties of high-strength fiber reinforced concrete. ACI Materials Journal, 89(5), 449–455. https://doi.org/10.30684/etj.28.12.13