Abstract
Recombinant tissue plasminogen activator (rt-PA) is used to restore patency and avoid inadvertent removal of peripheral and central venous catheters. rt-PA was reconstituted (1 mg/mL) then cryopreserved at -30 °C for 1, 2, 3, 6, 8, and 12 months and, then its stability was determined. After cryopreservation for one and two months, rt-PA kept more than 95% of its activity compared to standard samples, while cryopreservation for three months caused 8% loss of activity. However, after cryopreservation for six months or more, rt-PA retained only 87.5% or less activity compared to standard samples. Therefore, it is recommended that reconstituted rt-PA be cryopreserved at -30 °C for a maximum period of three months. © 2013 by the authors; licensee MDPI, Basel, Switzerland.
Author supplied keywords
Cite
CITATION STYLE
Alkatheri, A. (2013). Stability of recombinant tissue plasminogen activator at -30 °c over one year. Pharmaceuticals, 6(1), 25–31. https://doi.org/10.3390/ph6010025