Computer-tomographic verification of ultrasound-guided piriformis muscle injection: A feasibility study

19Citations
Citations of this article
71Readers
Mendeley users who have this article in their library.

Abstract

Background: Approximately 6% to 8% of lumbar pain cases, whether associated with radicular pain or not, may be attributed to the presence of piriformis muscle syndrome. Available treatments, among others, include pharmacotherapy, physical therapy, and injections of different substances into the muscle. Various methods have been used to confirm correct needle placement during these procedures, including electromyography (EMG), fluoroscopy, computed tomography (CT), or magnetic resonance imaging (MRI). Ultrasonography (US) has now become a widely used technique and therefore may be an attractive alternative for needle guidance when injecting this muscle. Conclusion: Ultrasound-guided puncture may be a reliable and simple procedure for injection of the piriformis muscle, as long as good education and training are provided to the operator. US has a number of advantages over traditional approaches, including accessibility and especially no ionizing radiation exposure for both health care providers and patients. Objective: The objective of this study was to assess the reliability of US in piriformis injection of patients with piriformis syndrome. Study Design: Feasibility study; 10 patients with piriformis muscle syndrome were injected with botulinum toxin A using a US-guided procedure. Then patients were administered 2 mL iodinated contrast and were then transferred to the CT scanner, where they underwent pelvic and hip imaging to assess intramuscular distribution of the iodinated contrast. Setting: Multidisciplinary Pain Management Department in Spain. Results: Of all 10 study patients (8 women, 2 men), 9 had intramuscular or intrafascial contrast distribution. Distribution did not go deeper than the piriformis muscle in any of the patients. The absence of contrast (intravascular injection) was not observed in any case. Limitations: The main limitation of our study is the use of ionizing radiation as confirmation technique.

Cite

CITATION STYLE

APA

Fabregat, G., Roselló, M., Asensio-Samper, J. M., Villanueva-Pérez, V. L., Martínez-Sanjuan, V., De Andrés, J., & Eichenberger, U. (2014). Computer-tomographic verification of ultrasound-guided piriformis muscle injection: A feasibility study. Pain Physician, 17(6), 507–513. https://doi.org/10.36076/ppj.2014/17/507

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free