Abstract

Background: Recent publications have focused on increased operating room (OR) throughput without increasing total OR time. The authors hypothesized that a system of parallel processing for lower extremity joint arthroplasties sustainably reduces nonoperative time and increases throughput. Methods: The high-throughput parallel processing strategy included neuraxial anesthesia performed in an "induction room" adjacent to the OR, patient selection, an additional circulating nurse, and end-of-case transfer of care to a recovery room nurse who transported the patient from the OR to recovery. Instruments and supplies were prepared in a dedicated sterile setup area. Data were extracted from administrative databases. Group comparisons used standard statistical methods; statistical process control was used to evaluate performance over time. Results: There were 688 historic control cases from 299 days over 16 months, and 905 high-throughput cases from 304 days spanning 24 consecutive months starting September 1, 2004. Throughput increased from 2.6 ± 0.7 (mean ± SD) to 3.4 ± 0.8 arthroplasties per day per room. Nonoperative time decreased by 36 min (or 50%) per case. Operative time also decreased by 14 min (12%) per case. The end time for the high-throughput OR day was only 16 min later than control. Nonoperative time, operative time, and throughput remained significantly improved after 2 yr of operation. Contribution margin increased 19.6%. Conclusion: Reorganizing the perioperative work process for total joint replacements sustainably increased OR throughput. Because joint arthroplasties generated a positive margin greater than the incremental cost, the high-throughput system improved financial performance. Copyright © 2008 The American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc.

Cite

CITATION STYLE

APA

Schubert, A., Smith, M. P., Sandberg, W. S., Foss, J., Massoli, K., Kanda, M., & Barsoum, W. (2008). High-throughput Operating Room System for Joint Arthroplasties Durably Outperforms Routine Processes. Anesthesiology, 109(1), 25–35. https://doi.org/10.1097/ALN.0b013e31817881c7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free