Relationship between exercise-induced heart rate increase and the formation of microbubbles and high-intensity transient signals in mechanical heart valve implanted patients

0Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

Abstract

Introduction: The formation and collapse of vapor-filled bubbles near a mechanical heart valve is called cavitation. Microbubbles can be detected in vivo by doppler ultrasonography (USG) as HITS (high intensity transient signals) in cranial circulation. We investigated the relationship between exercise induced heart rate increase and HITS formation in cranial circulation. Material and methods: Thirty-nine mechanical heart valve implanted (8 aortic valve replacement (AVR) + mitral valve replacement (MVR), 9 AVR, 22 MVR) patients aged 18-80 years old were included in our study. Microbubbles were counted in the left ventricular cavity via transthoracic echocardiography at rest per cardiac cycle. Afterwards transcranial Doppler USG was performed and HITS were counted in each patient's middle cerebral artery at 5 min duration. Subsequently an exercise test according to the Bruce protocol was performed. After achieving maximal heart rate, microbubbles in the left ventricle and HITS were counted again. Results: Microbubbles in the left ventricle and transcranial HITS increased after exercise significantly compared to resting values (15.79 ±10.91 microbubbles/beat vs. 26.51 ±18.00 microbubbles/beat, p < 0.001; 6.13 ±8.07 HITS/5 min vs. 13.15 ±15.87 HITS/5 min, p = 0.001). There was a significant correlation between microbubbles and HITS counts after peak exercise (r = 0.55, p < 0.001). Conclusions: In our study, we found that the microbubbles were increasing as the heart rate increased and more HITS were propelled to the cerebral circulation. As previously shown, HITS can alter cognitive functions. Therefore heart rate control is essential in mechanical heart valve patients to protect neurocognitive functions. Copyright © 2014 Termedia & Banach.

Cite

CITATION STYLE

APA

Sünbül, A., Kirbaş, A., Tanrikulu, N., Şengül, C., Daǧdeviren, B., & Işik, Ö. (2014). Relationship between exercise-induced heart rate increase and the formation of microbubbles and high-intensity transient signals in mechanical heart valve implanted patients. Archives of Medical Science, 10(4), 701–705. https://doi.org/10.5114/aoms.2013.34990

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free