Coupled ptychography and tomography algorithm improves reconstruction of experimental data

  • Kahnt M
  • Becher J
  • Brückner D
  • et al.
26Citations
Citations of this article
55Readers
Mendeley users who have this article in their library.
Get full text

Abstract

© 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement Three-dimensional (3D) x-ray microscopy by ptychographic tomography requires elaborate numerical reconstructions. We describe a coupled ptychography-tomography reconstruction algorithm and apply it to an experimental ptychographic x-ray computed tomography data set of a catalyst particle. Compared to the traditional sequential algorithm, in which ptychographic projections are reconstructed to serve as input for subsequent tomographic reconstruction, the coupled ptychography-tomography algorithm reconstructs the 3D volume with higher spatial resolution over a larger field of view. Coupling the data from different projections improves the overall reconstruction, and the ptychographic sampling in individual projections can be coarsened beyond the point of overlap between neighboring scan points, still leading to stable reconstructions.

Cite

CITATION STYLE

APA

Kahnt, M., Becher, J., Brückner, D., Fam, Y., Sheppard, T., Weissenberger, T., … Schroer, C. G. (2019). Coupled ptychography and tomography algorithm improves reconstruction of experimental data. Optica, 6(10), 1282. https://doi.org/10.1364/optica.6.001282