Multi-mode kernel principal component analysis–based incipient fault detection for pulse width modulated inverter of China Railway High-speed 5

43Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This article deals with incipient fault of insulated-gate bipolar transistors to improve the safety of traction systems of China Railway High-speed 5. Combining with the pulse width modulated strategy which makes signals variate periodically, the multi-mode kernel principal component analysis algorithm is proposed. It can effectively not only capture the tiny changes caused by incipient faults but also detect short-faults of insulated-gate bipolar transistors in electrical systems. In feature space of every mode, different thresholds will be formed corresponding to defined modes. The proposed scheme is tested in experimental setup of traction system of China Railway High-speed 5 with incipient fault and short-circuit fault, and experimental results show that the multi-mode kernel principal component analysis has superior monitoring performance compared to other five methods.

Cite

CITATION STYLE

APA

Chen, H., Jiang, B., Lu, N., & Mao, Z. (2017). Multi-mode kernel principal component analysis–based incipient fault detection for pulse width modulated inverter of China Railway High-speed 5. Advances in Mechanical Engineering, 9(10). https://doi.org/10.1177/1687814017727383