A new experimental setup has been designed for conducting experiments in a copper round pipe heat exchanger with inner diameter di=14.5mm and outer diameter do=16mm and length L = 1720 mm . By using two copper oxide nano concentrations of 0.1% and 0.3% with water as based fluid, the heat transfer rates have been obtained with helical twisted insert H/D=5 in turbulent flow condition. Reynolds number and friction factor with pressure gradient have been evaluated. The heat transfer rates of 0.1% conc. Nano-fluid with insert was found to be 13.77% more when compared to water.
CITATION STYLE
Ashok Reddy, K., & Hanmanthu, B. (2018). Performance Analysis of Water Based Copper Oxide Nano Fluids in Heat Exchanger with Twisted Insert. In IOP Conference Series: Materials Science and Engineering (Vol. 330). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/330/1/012111