Effects of permanent cardiac pacemaker implantation on vascular endothelial function, blood coagulation and cardiac function in patients with bradycardia

7Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

Changes in vascular endothelial function, blood coagulation and cardiac function indexes after the implantation of a permanent cardiac pacemaker in patients with bradycardia were investigated. A total of 53 healthy people and 117 patients with bradycardia in Jining First People's Hospital from January 2015 to August 2017 were selected. Factor VIII: coagulation (FVIII:C), von Willebr and factor (vWF), antithrombin activity (AT:A), D-dimmer (D-D), thrombomodulin (TM), tissue factor (TF), left ventricular ejection fraction (LVEF) and left ventricular end-systolic volume (LVESV) in the non-pacemaker group and the pacemaker group were significantly different from those in the control group (P<0.05), in which FVIII:C, vWF, D-D, TM, TF and LVESV were significantly higher than those in the control group, while LVEFs were significantly lower than that in the control group. After the implantation of a pacemaker, the FVIII:C, vWF, fibrinogen (FIB), D-D, TF and LVESV in patients were significantly higher than those before implantation (P<0.05), while the LVEF was significantly lower than that before implantation (P<0.05). In addition, in different pacemaker groups, there were no significant differences in blood coagulation and vascular endothelial indexes, but differences in cardiac function levels were obvious, in which LVEF in dual-chamber (DDD) pacemaker group was significantly higher than that in ventricular inhibited (VVI) pacemaker group, and LVESV in the former was significantly lower than that in the latter (P<0.05). Finally, here was no significant difference in the quality of life of patients implanted with different pacemakers (P>0.05), but the quality of life of patients in the DDD pacemaker group was better than that of patients in the VVI group. Therefore, implanting pacemakers in patients with bradycardia affects vascular endothelial function, blood coagulation, and cardiac function indexes in patients, and complications become less after the implantation of DDD pacemakers.

Cite

CITATION STYLE

APA

Zhang, X., Li, Y., Wang, N., Zhang, C., Zhang, D., & Li, Q. (2018). Effects of permanent cardiac pacemaker implantation on vascular endothelial function, blood coagulation and cardiac function in patients with bradycardia. Experimental and Therapeutic Medicine, 16(6), 4717–4721. https://doi.org/10.3892/etm.2018.6808

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free