Pseudo-outbreak of extremely drug-resistant Pseudomonas aeruginosa urinary tract infections due to contamination of an automated urine analyzer

15Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

By the end of May 2010, an increase in the number of urine specimens that were culture positive for extremely drug-resistant (XDR) Pseudomonas aeruginosa was observed in our 800-bed university hospital. This led to an infection control alert. No epidemiological link between the patients and no increase in the frequency of XDR P. aeruginosa in non-urine samples were observed. Therefore, a pseudo-outbreak due to analytical contamination in the laboratory was rapidly suspected. A prospective and retrospective search of cases was initiated, and the sampling of the automated urine analyzers used in the laboratory was performed. Antibiotypes were determined by disc diffusion, and genotypes were determined by pulsed-field gel electrophoresis (PFGE). From February to July 2010, 17 patients admitted to 12 different departments and 6 outpatients were included. The mixing device of the cytometric analyzer used for the numeration of urinary particles (Sysmex UF1000i) proved to be heavily contaminated. Isolates recovered from 12 patients belonged to the same antibiotype and PFGE type as the isolate recovered from the analyzer. Extensive disinfection with a broad-spectrum disinfectant and the replacement of the entire tubing was necessary to achieve the complete negativity of culture samples taken from the analyzer. A pseudo-outbreak caused by an XDR P. aeruginosa clone was proven to be due to the contamination of the cytometric analyzer for urinary sediment. Users of such analyzers should be aware that contamination can occur and should always perform culture either before the processing of the urine sample on the analyzer or on a distinct sample tube. Copyright © 2012, American Society for Microbiology. All Rights Reserved.

Cite

CITATION STYLE

APA

Hallin, M., Deplano, A., Roisin, S., Boyart, V., De Ryck, R., Nonhoff, C., … Denis, O. (2012). Pseudo-outbreak of extremely drug-resistant Pseudomonas aeruginosa urinary tract infections due to contamination of an automated urine analyzer. Journal of Clinical Microbiology, 50(3), 580–582. https://doi.org/10.1128/JCM.06268-11

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free