Radiation safety for anaesthesia providers in the orthopaedic operating room

17Citations
Citations of this article
53Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In many orthopaedic operating rooms, anaesthesia providers routinely wear lead aprons for protection from radiation, but some studies have questioned whether this is needed. We conducted a systematic review to identify studies that measured the amount of radiation that anaesthetists were exposed to in the orthopaedic operating room. Multiple studies have shown that at 1.5 m from the source of radiation, anaesthetists received no radiation, or amounts so small that a person would have to be present in an unreasonable number of operations to receive cumulative doses of any significance. Radiation doses at this distance were often at the limits of the sensitivity of the measuring dosimeter. We question the need to wear lead protection for anaesthesia providers who are routinely at 1.5 m or a greater distance from standard fluoroscopy units.

Cite

CITATION STYLE

APA

Rhea, E. B., Rogers, T. H., & Riehl, J. T. (2016, April 1). Radiation safety for anaesthesia providers in the orthopaedic operating room. Anaesthesia. Blackwell Publishing Ltd. https://doi.org/10.1111/anae.13400

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free