An effective process intensification strategy based on dividing walls shows promising energy-saving results for distillation processes. The three-product Petlyuk dividing wall distillation columns (DWDCs) are able to save approximately 30% energy in comparison with the traditional distillation columns. Furthermore, the four-product extended Petlyuk DWDC reduces about 50% of operation costs than conventional distillation sequences. Although researchers have extensively studied control schemes for the three-product Petlyuk DWDC, relatively little work has been done on the four-product extended Petlyuk DWDC. This paper studies feasible temperature control schemes containing temperature control scheme (TC), simplified temperature difference control scheme (STDC), and simplified double temperature difference control scheme (SDTDC) for the four-product extended Petlyuk DWDC. STDC and SDTDC are introduced so as to improve the dynamic performances with simple control schemes. All three control schemes are tested against a series of feed compositions and feed rate disturbances. Dynamic performances prove that the proposed STDC and SDTDC schemes are better at handling the inserted feed disturbances. These are very encouraging results for industrialization of the four-product extended Petlyuk DWDC in the future.
CITATION STYLE
Qian, X., Liu, R., Huang, K., Chen, H., Yuan, Y., Zhang, L., & Wang, S. (2020). Controllability comparison of the four-product petlyuk dividing wall distillation column using temperature control schemes. Processes, 8(1). https://doi.org/10.3390/pr8010116