Pengaruh Penggunaan Fan dan Debit Fluida terhadap Efisiensi Kerja Atmospheric Water Generator

  • Vidiyanto B
  • Aryadi W
  • et al.
N/ACitations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

PENGARUH PENGGUNAAN FAN DAN DEBIT FLUIDA TERHADAP EFISIENSI KERJA ATMOSPHERIC WATER GENERATOR The purposes of this study are to investigate the effect of condenser cooling fan addition and air flow rate on the performance of Atmospheric Water Generator (AWG). In this work, humid air from the environment was supplied into AWG at 15 lpm. Then, it was condensed in the system with and without using a condenser cooling fan. The fan air flow rate also varied from 0.09 m 3 /s to 0.16 m 3 /s in order to better assess AWG performance. The results showed that the use of a condenser cooling fan can improve the Coefficient of Performance (COP) and the efficiency of Atmospheric Water Generator. The average value of COPactual of 2.499 and the highest efficiency of 79.07% were achieved by an Atmosphere Water Generator equipped with a condenser cooling fan at air flow rate of 0.16 m 3 /s.