Abstract
The behavior of the leak and reverse currents in a bipolar-type alkaline water electrolyzer has been investigated using a bipolar-type electrolyzer which consists of two cells. The electrodes were nickel mesh, which are the conventional electrodes for alkaline water electrolyzers. The leak circuit could be expressed by a simple equation and a simple equivalent circuit for the cell performance and ionic resistance of the manifolds. The electrolyte was replaced by a gas-free electrolyte after electrolysis to classify the influence of the reverse current into the gas reaction and electrode active material. As a result, the dominant driving force of the reverse current was the active nickel-based materials on the Ni electrode. The redox couples on the electrode surface during the reverse current were estimated based on the measured cell voltages and redox potentials on a nickel electrode. The final potentials of both sides on the bipolar plate for the replacement conditions were higher than those for the non-replacement condition, because the hydrogen of the reductant was removed from the cathode electrolyte, and the balance of the reductant and oxidant would change to the oxidation side.
Author supplied keywords
Cite
CITATION STYLE
Uchino, Y., Kobayashi, T., Hasegawa, S., Nagashima, I., Sunada, Y., Manabe, A., … Mitsushima, S. (2018). Dependence of the reverse current on the surface of electrode placed on a bipolar plate in an alkaline water electrolyzer. Electrochemistry, 86(3), 138–144. https://doi.org/10.5796/electrochemistry.17-00102
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.