Safety of the transpulmonary ultrasound contrast agent NC100100: A clinical and haemodynamic evaluation in patients with suspected or proved coronary artery disease

21Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Objective - To evaluate the clinical and haemodynamic safety of NC100100, a new transpulmonary ultrasound contrast agent intended for vascular use. Design - Pulmonary artery pressures and gas exchange, left ventricular and systemic blood pressure and ECG were measured at baseline, after saline injection, and after each of two increasing doses of NC100100 injected intravenously. Patients - 30 patients who were evaluated for suspected coronary artery disease. Results - No change was detected in any of the haemodynamic variables, or in haematological or clinical chemical parameters. Blood gases were unchanged, as were heart rhythm and arterial oxygen saturation. No serious adverse reactions were reported. Conclusions - NC100100 appeared to be haemodynamically inert and safe in patients with coronary artery disease.

Author supplied keywords

Cite

CITATION STYLE

APA

Myreng, Y., Mølstad, P., Ytre-Arne, K., Aas, M., Stoksflod, L., Nossen, J., & Oftedal, B. (1999). Safety of the transpulmonary ultrasound contrast agent NC100100: A clinical and haemodynamic evaluation in patients with suspected or proved coronary artery disease. Heart, 82(3), 333–335. https://doi.org/10.1136/hrt.82.3.333

Register to see more suggestions