Liquid Distribution in Trickle-Bed Reactor

67Citations
Citations of this article
76Readers
Mendeley users who have this article in their library.

Abstract

Liquid Distribution in Trickle-Bed Reactor - The aim of this study is to develop techniques to qualify the efficiency of liquid distribution in trickle-bed reactors, using cold mockups. The experimental setup consists mainly in a 0.3-m-ID packed-bed column with three different plates used to vary the quality of inlet liquid distribution. Liquid distribution has been qualified using several techniques: global pressure drop measurements, global RTD (Residence-Time Distribution) of the liquid, local heat transfer probes, capacitance tomography, collector at the bottom of the reactor with nine equal zones. The bed pressure drop and the overall external liquid saturation decrease when the maldistribution increases; quantitative information is however difficult to obtain this way. Global RTD of the liquid allows quantifying of the average liquid distribution in the bed. The local thermal sensors give an indication of local liquid velocity and indicate possible local maldistribution of the liquid (scale mm) even when global distribution is good. Concerning the results obtained with the collector, a maldistribution index is defined, ranging from O (ideal distribution) to I (worst possible distribution), and the influence of the different operating parameters (gas and liquid velocities, particle shape) is discussed.

Cite

CITATION STYLE

APA

Marcandelli, C., Lamine, A. S., Bernard, J. R., & Wild, G. (2000). Liquid Distribution in Trickle-Bed Reactor. Oil and Gas Science and Technology, 55(4), 407–415. https://doi.org/10.2516/ogst:2000029

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free