Abstract
The micro-focusing performance for hard X-rays of a fixed-geometry elliptical Kirkpatrick-Baez (K-B) mirrors assembly fabricated, tested and finally implemented at the micro-probe beamline 8-BM of the Advanced Photon Source is reported. Testing of the K-B mirror system was performed at the optics and detector test beamline 1-BM. K-B mirrors of length 80 mm and 60 mm were fabricated by profile coating with Pt metal to produce focal lengths of 250 mm and 155 mm for 3 mrad incident angle. For the critical angle of Pt, a broad bandwidth of energies up to 20 keV applies. The classical K-B sequential mirror geometry was used, and mirrors were mounted on micro-translation stages. The beam intensity profiles were measured by differentiating the curves of intensity data measured using a wire-scanning method. A beam size of 1.3 μm (V) and 1.2 μm (H) was measured with monochromatic X-rays of 18 keV at 1-BM. After installation at 8-BM the measured focus met the design requirements. In this paper the fabrication and metrology of the K-B mirrors are reported, as well as the focusing performances of the full mirrors-plus-mount set-up at both beamlines. © 2014 International Union of Crystallography.
Author supplied keywords
Cite
CITATION STYLE
Kujala, N., Marathe, S., Shu, D., Shi, B., Qian, J., Maxey, E., … Assoufid, L. (2014). Kirkpatrick-Baez mirrors to focus hard X-rays in two dimensions as fabricated, tested and installed at the Advanced Photon Source. Journal of Synchrotron Radiation, 21(4), 662–668. https://doi.org/10.1107/S1600577514006493