Abstract
Objective: To evaluate early keratometric and refractive results after intra-corneal rings surgery in keratoconus patients. Method: 50 eyes of 25 patients with keratoconus within stage 2 and 3, underwent intra-stromal corneal rings surgery by using the femtosecond surgical laser, one month after surgery, corneal keratometries and patient refraction were compared vs preoperative ones. Results: Mean pre-operative low keratometry was 48.8 ± 3.65 D vs. 46.44 ± 3.65 D post-operative (p < 0.005). Mean pre-operative high keratometry was 53.92 ± 4.50 vs. 49.65 ± 4.15 post-operative (p < 0.005). Mean pre-operative spherical equivalent was −7.39 ± 2.42 D vs. −3.48 ± 2.47 D post-operative (p < 0.005). Mean pre-operative cylinder was −5.65 ± 2.02 D vs. −3.48 ± 2.47 D post-operative (p < 0.005). Conclusions: Corneal keratometries, spherical equivalent and corneal cylinder, significant decrease at one month after intra-stromal corneal rings surgery in keratoconus patients.
Author supplied keywords
Cite
CITATION STYLE
Ramírez, M., Manzanillo, C., Estrada, A., Cabrera, E., Ordoñez-Ranz, G., Romero, E., & Hernández-Quintela, E. (2022). Early keratometric and refractive results after intra-corneal rings surgery in keratoconus patients. Cirugia y Cirujanos (English Edition), 90(Supplement 1), 92–95. https://doi.org/10.24875/CIRU.22000018
Register to see more suggestions