Abstract
This paper presents detailed measurements of the filmcooling effectiveness for three single, scaled-up film-cooling hole geometries. The hole geometries investigated include a cylindrical hole and two holes with a diffuser shaped exit portion (i.e. a fanshaped and a laidback fanshaped hole). The flow conditions considered are the crossfiow Mach number at the hole entrance side (up to 0.6), the crossfiow Mach number at the hole exit side (up to 1.2), and the blowing ratio (up to 2). The coolant-to-mainflow temperature ratio is kept constant at 0.54. The measurements are performed by means of an infrared camera system which provides a twodimensional distribution of the film-cooling effectiveness in the nearfield of the cooling hole down to x/D=10. As compared to the cylindrical hole, both expanded holes show significantly improved thermal protection of the surface downstream of the ejection location, particularly at high blowing ratios. The laidback fanshaped hole provides a better lateral spreading of the ejected coolant than the fanshaped hole which leads to higher laterally averaged filmcooling effectiveness. Coolant passage crossflow Mach number and orientation strongly affect the flowfield of the jet being ejected from the hole and, therefore, have an important impact on film-cooling performance.
Cite
CITATION STYLE
Gritsch, M., Schulz, A., & Wittig, S. (1997). Adiabatic wall effectiveness measurements of film-cooling holes with expanded exits. In Proceedings of the ASME Turbo Expo (Vol. 3). American Society of Mechanical Engineers (ASME). https://doi.org/10.1115/97-GT-164