The Geometric Correction Method for zircon (U-Th)He chronology: correcting systematic error and assigning uncertainties to alpha-ejection corrections and eU concentrations

3Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

The conventional zircon (U-Th) = He (ZHe) method typically uses microscopy measurements of the dated grain together with the assumption that the zircon can be appropriately modeled as a geometrically perfect tetragonal or ellipsoidal prism in the calculation of volume (V ), alpha-ejection correction (FT), equivalent spherical radius (RFT), effective uranium concentration (eU), and corrected (U-Th) = He date. Here, we develop a set of corrections for systematic error and determine uncertainties to be used in the calculation of the above parameters for zircon, using the same methodology as Zeigler et al. (2023) for apatite. Our approach involved acquiring both 2D microscopy measurements and high-resolution 3D nano-computed tomography (CT) data for a suite of 223 zircon grains from nine samples showcasing a wide range of morphology, size, age, and lithological source, calculating the V , FT, and RFT values for the 2D and 3D measurements and comparing the 2D vs. 3D results. We find that the values derived from the 2D microscopy data overestimate the true 3D V , FT, and RFT values for zircon, with one exception (V of ellipsoidal grains). Correction factors for this misestimation determined by regressing the 3D vs. 2D data range from 0.81-1.04 for V , 0.97-1.0 for FT, and 0.92-0.98 for RFT, depending on zircon geometry. Uncertainties (1s) derived from the scatter of data around the regression line are 13 %-21 % for V , 5 %-1 % for FT, and 8 % for RFT, again depending on zircon morphologies. Like for apatite, the main control on the magnitude of the corrections and uncertainties is grain geometry, with grain size being a secondary control on FT uncertainty. Propagating these uncertainties into a real dataset (N D 28 ZHe analyses) generates 1s uncertainties of 12 %-21 % in eU and 3 %-7 % in the corrected ZHe date when both analytical and geometric uncertainties are included. Accounting for the geometric corrections and uncertainties is important for appropriately reporting, plotting, and interpreting ZHe data. For both zircon and apatite, the Geometric Correction Method is a practical and straightforward approach for calculating more accurate (U-Th) = He data and for including geometric uncertainty in eU and date uncertainties.

Cite

CITATION STYLE

APA

Zeigler, S. D., Baker, M., Metcalf, J. R., & Flowers, R. M. (2024). The Geometric Correction Method for zircon (U-Th)He chronology: correcting systematic error and assigning uncertainties to alpha-ejection corrections and eU concentrations. Geochronology, 6(2), 199–226. https://doi.org/10.5194/gchron-6-199-2024

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free