Abstract
The paper is concerned with the thermodynamic analysis of a multi-stream heat exchanger system for the Allam cycle and the development of a regenerator heat flow chart. The multi-stream heat exchanger thermodynamic analysis and development procedure are described in detail. The regenerator system constructed of five double-flow heat exchangers has 2.5% lower heat power than the ideal heat exchanging system. Besides, a subsequent flow interaction principle for the transfer of a maximal heat amount is proposed: it is necessary to begin with the cooling of the heating flows with minimal temperatures.
Cite
CITATION STYLE
Rogalev, A., Rogalev, N., Kindra, V., Vegera, A., & Zonov, A. (2021). Multi-stream heat exchanger for oxy-fuel combustion power cycle. In AIP Conference Proceedings (Vol. 2323). American Institute of Physics Inc. https://doi.org/10.1063/5.0041543