Benefits of VISION max automated crossmatching in comparison with manual crossmatching: A multidimensional analysis

7Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

Abstract

Background VISION Max (Ortho-Clinical Diagnostics, Raritan, NJ, USA) is a newly introduced automated blood bank system. Cross-matching (XM) is an important test confirming safety by simulating reaction between packed Red Blood Cells (RBCs) and patient blood in vitro before transfusion. We assessed the benefits of VISION Max automated XM (A-XM) in comparison with those of manual XM (M-XM) by using multidimensional analysis (cost-effectiveness and quality improvement). Materials and methods In a total of 327 tests (130 patients), results from A-XM and M-XM were compared. We assessed the concordance rate, risk priority number (RPN), turnaround time, hands-on time, and the costs of both methods. We further simulated their annual effects based on 37,937 XM tests in 2018. Results The concordance rate between A-XM and M-XM was 97.9% (320/327, kappa = 0.83), and the seven discordant results were incompatible for transfusion in A-XM, while compatible for transfusion in M-XM. None of the results was incompatible for transfusion in A-XM, while compatible for transfusion in M-XM, meaning A-XM detect agglutination more sensitively and consequently provides a more safe result than M-XM. A-XM was estimated to have a 6.3-fold lower risk (229 vs. 1,435 RPN), shorter turnaround time (19.1 vs. 23.3 min, P < 0.0001), shorter hands-on time (1.1 vs. 5.3 min, P < 0.0001), and lower costs per single test than M-XM (1.44 vs. 2.70 USD). A-XM permitted annual savings of 46 million RPN, 15.1 months of daytime workers’ labor, and 47,042 USD compared with M-XM. Conclusion This is the first attempt to implement A-XM using VISION Max. VISION Max A-XM appears to be a safe, practical, and reliable alternative for pre-transfusion workflow with the potential to improve quality and cost-effectiveness in the blood bank.

Cite

CITATION STYLE

APA

Chung, H. J., Hur, M., Choi, S. G., Lee, H. K., Lee, S., Kim, H., … Yun, Y. M. (2019). Benefits of VISION max automated crossmatching in comparison with manual crossmatching: A multidimensional analysis. PLoS ONE, 14(12). https://doi.org/10.1371/journal.pone.0226477

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free