An analysis of reinforced concrete supporting structures of more than a dozen liquid gas tanks mounted on tower support structures located at different sites on Poland's territory is presented. Stability testing of the degraded structures was carried out over a period of 30 years and pointed out significant defects that prevented safe operation of the tanks containing hazardous medium. Analysing complex stress states, as well as displacements of shell structure components, the authors developed a concept of strengthening the structures. Initial repair works, which had been carried out without proper supervision, failed to meet the mandatory requirements and were not compatible with the original design solutions. After several years of operation of the reinforced structures, their degradation states were assessed again. The next stage of repair works was carried out under the supervision of the authors together with authorized representatives of the investors.

Cite

CITATION STYLE

APA

Krentowski, J. R., & Knyziak, P. (2017). Degradation and Reinforcement of Industrial Gas Tank Support Structures. Thirty-Year Long Monitoring. In IOP Conference Series: Materials Science and Engineering (Vol. 245). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/245/3/032054